MadgeTech HiTemp140 | High Temperature ...
Temperature Sensor | 100 O Platinum RTD |
Temperature Resolution | 0.01 °C (0.018 °F) |
Temperature Calibrated Accuracy | ±0.1 °C/±0.18 °F (20 °C to +140 °C/68 °F to +284 °F) ±0.3 °C/±0.54 °F (-20 °C to +19.99 °C/-4 °F to +67.98 °F) ±0.4 °C/±0.72 ºF (-40 °C to -20.01 °C/-40 °F to +-4.02 °F) |
Probe Temperature Range |
-200 °C to +260 °C (-328 °F to +500 °F) (Body of Logger Cannot Exceed 140 °C) |
The HiTemp140 is a submersible, high temperature data logger built for use in harsh environments. This best-seller is extremely versatile and can be tailored to the application with various probe lengths and styles available.
The HiTemp140 can withstand temperatures ranging from -40 °C to +140 °C (-40 °F to +284 °F), but is capable of measuring extended temperatures up to 260 °C (500 °F) (probe dependent). With a storage capacity of up to 65,536 time and date stamped readings, the HiTemp140 can be programmed for immediate start or delayed start up to 18 months in advance.
The HiTemp140 is compatible with the latest MadgeTech 4 Software making starting, stopping, and downloading simple and easy. Graphical, tabular, and summary data is provided for analysis and can be viewed as customizable engineering units.
Body of data logger cannot exceed 140 °C (284 °F), but can extend to higher temperatures when used with MadgeTech’s thermal barrier options.
Learn More about the HiTemp140 Series here: https://www.pacificsensortech.com.au/hitemp140
Notice: The HiTemp140-FP (flexible probe) is not ideal for steam sterilization applications above 121 °C/1.1 bar. For more information, please refer to the preventative maintenance procedure called out in the HiTemp140-FP Data Sheet.
Probe Type | Material | Operating Environment | Probe Measurement Range |
---|---|---|---|
Rigid | Metal | Temperature: -40 °C to +140 °C (-40 °F to +284 °F) Humidity: 0 %RH to 100 %RH Pressure: 0.002 PSIA to 100 PSIA |
Temperature: -200 °C to +260 °C (-328 °F to +500 °F) Probe only. Body must not exceed Operating Environment |
Rigid Transitional Diameter (TD) | Metal | Temperature: -40 °C to +140 °C (-40 °F to +284 °F) Humidity: 0 %RH to 100 %RH Pressure: 0.002 PSIA to 100 PSIA |
Temperature: -200 °C to +260 °C (-328 °F to +500 °F) Probe only. Body must not exceed Operating Environment |
Flexible (FP) | Bendable PTFE | Temperature: -40 °C to +140 °C (-40 °F to +284 °F) Humidity: 0 %RH to 100 %RH Pressure: 0.002 PSIA to 60 PSIA |
Temperature: -60 °C to +260 °C (-76 °F to 500 °F) Probe only. Body must not exceed Operating Environment |
PT | Bendable Metal | Temperature: -40 °C to +140 °C (-40 °F to +284 °F) Humidity: 0 %RH to 100 %RH Pressure: 0.002 PSIA to 100 PSIA |
Temperature: -200 °C to +350 °C (-328 °F to +662 °F) Probe only. Body must not exceed Operating Environment |
Fast Response (FR) | Metal | Temperature: -40 °C to +140 °C (-40 °F to +284 °F) Humidity: 0 %RH to 100 %RH Pressure: 0.002 PSIA to 100 PSIA |
Temperature: -200 °C to +260 °C (-328 °F to +500 °F) Probe only. Body must not exceed Operating Environment |
To contact Pacific Sensor Technologies Pty Ltd about MadgeTech HiTemp140 | High Temperature Data logger use Get a quote.
Temperature Sensor | 100 O Platinum RTD |
Temperature Resolution | 0.01 °C (0.018 °F) |
Temperature Calibrated Accuracy | ±0.1 °C/±0.18 °F (20 °C to +140 °C/68 °F to +284 °F) ±0.3 °C/±0.54 °F (-20 °C to +19.99 °C/-4 °F to +67.98 °F) ±0.4 °C/±0.72 ºF (-40 °C to -20.01 °C/-40 °F to +-4.02 °F) |
Probe Temperature Range |
-200 °C to +260 °C (-328 °F to +500 °F) (Body of Logger Cannot Exceed 140 °C) |
The HiTemp140 is a submersible, high temperature data logger built for use in harsh environments. This best-seller is extremely versatile and can be tailored to the application with various probe lengths and styles available.
The HiTemp140 can withstand temperatures ranging from -40 °C to +140 °C (-40 °F to +284 °F), but is capable of measuring extended temperatures up to 260 °C (500 °F) (probe dependent). With a storage capacity of up to 65,536 time and date stamped readings, the HiTemp140 can be programmed for immediate start or delayed start up to 18 months in advance.
The HiTemp140 is compatible with the latest MadgeTech 4 Software making starting, stopping, and downloading simple and easy. Graphical, tabular, and summary data is provided for analysis and can be viewed as customizable engineering units.
Body of data logger cannot exceed 140 °C (284 °F), but can extend to higher temperatures when used with MadgeTech’s thermal barrier options.
Learn More about the HiTemp140 Series here: https://www.pacificsensortech.com.au/hitemp140
Notice: The HiTemp140-FP (flexible probe) is not ideal for steam sterilization applications above 121 °C/1.1 bar. For more information, please refer to the preventative maintenance procedure called out in the HiTemp140-FP Data Sheet.
Probe Type | Material | Operating Environment | Probe Measurement Range |
---|---|---|---|
Rigid | Metal | Temperature: -40 °C to +140 °C (-40 °F to +284 °F) Humidity: 0 %RH to 100 %RH Pressure: 0.002 PSIA to 100 PSIA |
Temperature: -200 °C to +260 °C (-328 °F to +500 °F) Probe only. Body must not exceed Operating Environment |
Rigid Transitional Diameter (TD) | Metal | Temperature: -40 °C to +140 °C (-40 °F to +284 °F) Humidity: 0 %RH to 100 %RH Pressure: 0.002 PSIA to 100 PSIA |
Temperature: -200 °C to +260 °C (-328 °F to +500 °F) Probe only. Body must not exceed Operating Environment |
Flexible (FP) | Bendable PTFE | Temperature: -40 °C to +140 °C (-40 °F to +284 °F) Humidity: 0 %RH to 100 %RH Pressure: 0.002 PSIA to 60 PSIA |
Temperature: -60 °C to +260 °C (-76 °F to 500 °F) Probe only. Body must not exceed Operating Environment |
PT | Bendable Metal | Temperature: -40 °C to +140 °C (-40 °F to +284 °F) Humidity: 0 %RH to 100 %RH Pressure: 0.002 PSIA to 100 PSIA |
Temperature: -200 °C to +350 °C (-328 °F to +662 °F) Probe only. Body must not exceed Operating Environment |
Fast Response (FR) | Metal | Temperature: -40 °C to +140 °C (-40 °F to +284 °F) Humidity: 0 %RH to 100 %RH Pressure: 0.002 PSIA to 100 PSIA |
Temperature: -200 °C to +260 °C (-328 °F to +500 °F) Probe only. Body must not exceed Operating Environment |