MadgeTech Autoclave Validation Data ...
The AVS140-1 consists of a NIST traceable high temperature data logger, an IFC400 Interface Cable and the MadgeTech 4 Secure Software providing tools to users to assist with FDA 21 CFR Part 11 compliance.
The AVS140-1 kit includes:
Learn More: https://www.pacificsensortech.com.au/sterilizer-autoclave-validation-hitemperature-datalogger-kit-avs140-1
High Temperature Data Logger specifications:
Temperature Sensor |
100 ? Platinum RTD |
Temperature Resolution |
0.01 °C (0.02 °F) |
Temperature Calibrated Accuracy |
±0.1 °C/±0.18 °F (20 °C to +140 °C/68 °F to +284 °F) |
Probe Temperature Range |
-200 °C to +260 °C (-328 °F to +500 °F) |
Memory |
32,700 |
|||||||
Reading Rate |
1 reading every second up to 1 reading every 24 hours |
|||||||
Baud Rate |
125,000 |
|||||||
Battery Life |
1 year typical (1 minute reading rate at 25 °C/77 °F) |
|||||||
Material |
316 Stainless Steel |
|||||||
Dimensions |
|
|||||||
IP Rating |
IP68 |
|||||||
Submersible |
Yes |
|||||||
Operating Environment |
-40 °C to +140 °C (-40 °F to +284 °F) |
|||||||
Required Interface Package |
IFC400 |
|||||||
Approvals |
CE |
To contact Pacific Sensor Technologies Pty Ltd about MadgeTech Autoclave Validation Data Loggers/System | AVS140-1 use Get a quote.
The AVS140-1 consists of a NIST traceable high temperature data logger, an IFC400 Interface Cable and the MadgeTech 4 Secure Software providing tools to users to assist with FDA 21 CFR Part 11 compliance.
The AVS140-1 kit includes:
Learn More: https://www.pacificsensortech.com.au/sterilizer-autoclave-validation-hitemperature-datalogger-kit-avs140-1
High Temperature Data Logger specifications:
Temperature Sensor |
100 ? Platinum RTD |
Temperature Resolution |
0.01 °C (0.02 °F) |
Temperature Calibrated Accuracy |
±0.1 °C/±0.18 °F (20 °C to +140 °C/68 °F to +284 °F) |
Probe Temperature Range |
-200 °C to +260 °C (-328 °F to +500 °F) |
Memory |
32,700 |
|||||||
Reading Rate |
1 reading every second up to 1 reading every 24 hours |
|||||||
Baud Rate |
125,000 |
|||||||
Battery Life |
1 year typical (1 minute reading rate at 25 °C/77 °F) |
|||||||
Material |
316 Stainless Steel |
|||||||
Dimensions |
|
|||||||
IP Rating |
IP68 |
|||||||
Submersible |
Yes |
|||||||
Operating Environment |
-40 °C to +140 °C (-40 °F to +284 °F) |
|||||||
Required Interface Package |
IFC400 |
|||||||
Approvals |
CE |
To contact Pacific Sensor Technologies Pty Ltd about MadgeTech Autoclave Validation Data Loggers/System | AVS140-1 use Get a quote.