Product characteristics |
Number of inputs and outputs |
Number of digital outputs: 2; Number of analogue outputs: 1 |
Process connection |
threaded connection M18 x 1,5 internal thread |
|
Application |
Special feature |
Gold-plated contacts |
Media |
water; glycol solutions; air; oils |
Note on media |
low-viscosity oils with viscosity: ≤ 40 mm²/s (40 °C) |
high-viscosity oils with viscosity: > 40 mm²/s (40 °C) |
|
Medium temperature [°C] |
-20...90 |
Pressure rating [bar] |
100 |
Pressure rating [Mpa] |
10 |
MAWP (for applications according to CRN) [bar] |
100 |
|
Electrical data |
Operating voltage [V] |
18...30 DC |
Current consumption [mA] |
< 100 |
Protection class |
III |
Reverse polarity protection |
yes |
Power-on delay time [s] |
10 |
|
Inputs / outputs |
Number of inputs and outputs |
Number of digital outputs: 2; Number of analogue outputs: 1 |
|
Outputs |
Total number of outputs |
2 |
Output signal |
switching signal; analogue signal; frequency signal; IO-Link; (configurable) |
Electrical design |
PNP/NPN |
Number of digital outputs |
2 |
Output function |
normally open / normally closed; (parameterisable) |
Max. voltage drop switching output DC [V] |
2.5 |
Permanent current rating of switching output DC [mA] |
250 |
Number of analogue outputs |
1 |
Analogue current output [mA] |
4...20; (scalable) |
Max. load [Ω] |
350 |
Short-circuit protection |
yes |
Type of short-circuit protection |
pulsed |
Overload protection |
yes |
Frequency of the output [Hz] |
0...1000 |
|
Measuring/setting range |
Probe length L [mm] |
45 |
Operating mode |
relative; absolutely liquid; absolutely gaseous; (absolute: reference measurement recommended) |
Note on factory setting |
|
|
Temperature monitoring |
Measuring range [°C] |
-20...90 |
Resolution [°C] |
0.2 |
|
Liquid media - absolute operating mode |
Setting range [m/s] |
0.04...3 |
Greatest sensitivity [m/s] |
0.04...3 |
|
Liquid media - relative operating mode |
Setting range [m/s] |
0.04...6 |
Greatest sensitivity [m/s] |
0.04...3 |
|
Gases - operating mode "absolute" |
Setting range [m/s] |
0...100 |
Greatest sensitivity [m/s] |
30...100 |
|
Gases - operating mode "relative" |
Setting range [m/s] |
0...200 |
Greatest sensitivity [m/s] |
30...100 |
|
Accuracy / deviations |
Temperature drift [cm/s x 1/K] |
0,003 m/s x 1/K (< 20 °C; > 70 °C) |
Temperature gradient [K/min] |
100 |
|
Absolute operating mode |
Repeatability |
0,05 m/s; (water; flow velocity: 0,05...3 m/s) |
|
Relative operating mode |
Accuracy |
± (7 % MW + 2 % MEW); (for relative mode in the range of maximum sensitivity under the following conditions:; water: 20...70 °C; inlet length: 1.5 m; DN25 (DIN 2448); mounting position according to instructions; Accuracy can differ for other media and mounting positions.) |
Repeatability |
0,05 m/s; (water; flow velocity: 0,05...3 m/s) |
|
Temperature monitoring |
Temperature drift |
± 0,005 K/°C |
Accuracy [K] |
± 0,3 / ± 1; (water; flow velocity: 0,3...3 m/s / air; flow velocity: > 10 m/s) |
|
Response times |
Response time [s] |
0.5; (T09; water; glycol: 0,8 s; air: 7 s; oil: 1,8 s; each T09) |
|
Temperature monitoring |
Dynamic response T05 / T09 [s] |
1,5 (T09); (water; flow velocity: 0,3...3 m/s) |
|
Software / programming |
Parameter setting options |
hysteresis / window; normally open / normally closed; switching logic; current/frequency output; medium selection; Damping; Teach function; display can be rotated and switched off; standard unit of measurement; process value colour |
|
Interfaces |
Communication interface |
IO-Link |
Transmission type |
COM2 (38,4 kBaud) |
IO-Link revision |
1.1 |
SDCI standard |
IEC 61131-9 |
Profiles |
Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis |
SIO mode |
yes |
Required master port type |
A |
Process data analogue |
2 |
Process data binary |
2 |
Min. process cycle time [ms] |
3 |
Supported DeviceIDs |
Type of operation |
DeviceID |
Factory setting / ModE = (REL) |
533 |
ModE = (LIQU) |
540 |
ModE = (GAS) |
547 |
|
|
Operating conditions |
Ambient temperature [°C] |
-40...80 |
Storage temperature [°C] |
-40...100 |
Protection |
IP 65; IP 67 |
|
Tests / approvals |
EMC |
|
Shock resistance |
DIN EN 60068-2-27 |
50 g (11 ms) |
|
Vibration resistance |
DIN EN 60068-2-6 |
20 g (10...2000 Hz) |
|
UL approval |
|
|
Mechanical data |
Weight [g] |
314 |
Materials |
stainless steel (1.4404 / 316L); stainless steel (1.4310 / 301); PBT-GF20; PBT-GF30 |
Materials (wetted parts) |
stainless steel (1.4404 / 316L); Gasket: FKM |
Process connection |
threaded connection M18 x 1,5 internal thread |
|
Displays / operating elements |
Display |
Display unit |
6 x LED, green (%, m/s, l/min, m³/h, °C, 10³) |
switching status |
2 x LED, yellow |
measured values |
alphanumeric display, red/green 4-digit |
|
|
Remarks |
Remarks |
MW = measured value |
MEW = Final value of the measuring range |
|
Pack quantity |
1 pcs. |
|
Electrical connection |
Connection |
Connector: 1 x M12; Contacts: gold-plated |