Diesel Generator | 220kVA, 3 Phase, with Engine | ED220CUYE/3
Diesel Generator | 220kVA, 3 Phase, with Engine | ED220CUYE/3
Diesel Generator | 220kVA, 3 Phase, with Engine | ED220CUYE/3
Diesel Generator | 220kVA, 3 Phase, with Engine | ED220CUYE/3
Diesel Generator | 220kVA, 3 Phase, with Engine | ED220CUYE/3
Diesel Generator | 220kVA, 3 Phase, with Engine | ED220CUYE/3
The Cummins powered ED220CUYE/3 is a 220kVA three phase standby diesel generator.
Description
Documents
42 Recent ViewsCall for more details
Complete with Crossley SLG series single bearing, 4-pole, brushless alternator, remote start/stop control system, 300 litre fuel tank, weather protective acoustic canopy and Cummins engine. Welling and Crossley Cummins powered generating sets are fully integrated power generation systems that are stringently tested to provide optimum performance, reliability, and versatility for standby applications.
Product Features:
Heavy duty fabricated steel baseframe The complete generating set is mounted as a whole onto a heavy duty fabricated steel baseframe. Anti-vibration pads are fixed between the engine and alternator feet, and the baseframe, ensuring complete vibration isolation of the rotating assembly.
Bunded Fuel Tank (AS 1940-2004 compliant) The fuel tank is fully bunded and complies fully with relevant sections in AS 1940-2004. It has a secondary containment compound with a capacity as big or bigger than that of the tank, and is made of surface coated steel. This compound is designed to sufficiantly retain spillage and enable recovery of any spillage. For more information regarding AS 1940-2004 compliance refer to the standard, or contact us.
Battery Charger This trickle charge battery charger ensures that your generator can start up when needed. It has both 12v and 24v charging capabilities.
Control Panel with Emergency Stop button This control panel monitors the controls of a single unit to achieve automatic start/stop, data measuring/monitoring, alarm protection and three remote systems (remote control, remote measuring and remote communication). The controller adopts large liquid crystal display (LCD) and has a 32 bit micro-processor with precision parameters for measuring, fixed value adjustment, time setting and threshold adjustment.
Prime or Standby Power
Standby: kVA @ 0.8 pf These ratings are applicable for supplying continuous electrical power (at variable loads) in the event of a utility power failure. No overload is permitted on these ratings. Minimum output from alternators are peak continuous rated (as defined in 1SO 8528-3 @ 27°C. Annual hour limitation: 500 hours).
Prime (continuous): kVA @ 0.8 pf. (Divide standby rating by 1.1). Available for continuous electrical output. There is no hour limitation. 10% overload is available 1 hour in 12. The generating set and this specification is designed for environmental conditions of up to 27°C, up to 152.4 m above sea level and up to 60% relative humidity. Ratings at 0.8 pf.
ProductSpecifications:
Alternator
Alternator Model: Crossley SLG Series
Electric Power: Three Phase
Active Rating: 220 kVA at 0.8 pf (Standby)
Power: 176 kW
Voltage: 415V
Frequency: 50Hz
Engine
Engine Model: Cummins 6CTAA8.3-G2
Engine Speed: 1500 rpm
Cylinder No.: 6TA
Cubic Capacity: 8.3 L
Bore / Stroke: 114 x 135 mm
Compression Ratio: 18 : 1
Aspiration: Turbocharged
Starter Voltage: 24V
Flywheel ( Max. Continuous Power): 207 kW
Combustion Air Flow: 25 m³/min
Cooling Air Flow: 700 m³/min
Cooling System: Radiator Cooled
Heat Rejection to Cooling System: 200 kW
Exhaust Gas Flow: 75 m³/min
Exhaust Gas Temperature: 550°C
Fuel Type: Diesel
Fuel Tank Capacity: 400 L
Approx. Fuel Consumption (Continuous): 50 L/hr
Approx. Fuel Consumption (Standby): 58 L/hr
Generator
Dimensions (L x W x H): 3800 x 1300 x 1950 mm (L x W x H)
To contact Welling & Crossley about Welling and Crossley Diesel Generator | 220kVA, 3 Phase, with Engine | ED220CUYE/3 use Get a quote.
Complete with Crossley SLG series single bearing, 4-pole, brushless alternator, remote start/stop control system, 300 litre fuel tank, weather protective acoustic canopy and Cummins engine. Welling and Crossley Cummins powered generating sets are fully integrated power generation systems that are stringently tested to provide optimum performance, reliability, and versatility for standby applications.
Product Features:
Heavy duty fabricated steel baseframe The complete generating set is mounted as a whole onto a heavy duty fabricated steel baseframe. Anti-vibration pads are fixed between the engine and alternator feet, and the baseframe, ensuring complete vibration isolation of the rotating assembly.
Bunded Fuel Tank (AS 1940-2004 compliant) The fuel tank is fully bunded and complies fully with relevant sections in AS 1940-2004. It has a secondary containment compound with a capacity as big or bigger than that of the tank, and is made of surface coated steel. This compound is designed to sufficiantly retain spillage and enable recovery of any spillage. For more information regarding AS 1940-2004 compliance refer to the standard, or contact us.
Battery Charger This trickle charge battery charger ensures that your generator can start up when needed. It has both 12v and 24v charging capabilities.
Control Panel with Emergency Stop button This control panel monitors the controls of a single unit to achieve automatic start/stop, data measuring/monitoring, alarm protection and three remote systems (remote control, remote measuring and remote communication). The controller adopts large liquid crystal display (LCD) and has a 32 bit micro-processor with precision parameters for measuring, fixed value adjustment, time setting and threshold adjustment.
Prime or Standby Power
Standby: kVA @ 0.8 pf These ratings are applicable for supplying continuous electrical power (at variable loads) in the event of a utility power failure. No overload is permitted on these ratings. Minimum output from alternators are peak continuous rated (as defined in 1SO 8528-3 @ 27°C. Annual hour limitation: 500 hours).
Prime (continuous): kVA @ 0.8 pf. (Divide standby rating by 1.1). Available for continuous electrical output. There is no hour limitation. 10% overload is available 1 hour in 12. The generating set and this specification is designed for environmental conditions of up to 27°C, up to 152.4 m above sea level and up to 60% relative humidity. Ratings at 0.8 pf.
ProductSpecifications:
Alternator
Alternator Model: Crossley SLG Series
Electric Power: Three Phase
Active Rating: 220 kVA at 0.8 pf (Standby)
Power: 176 kW
Voltage: 415V
Frequency: 50Hz
Engine
Engine Model: Cummins 6CTAA8.3-G2
Engine Speed: 1500 rpm
Cylinder No.: 6TA
Cubic Capacity: 8.3 L
Bore / Stroke: 114 x 135 mm
Compression Ratio: 18 : 1
Aspiration: Turbocharged
Starter Voltage: 24V
Flywheel ( Max. Continuous Power): 207 kW
Combustion Air Flow: 25 m³/min
Cooling Air Flow: 700 m³/min
Cooling System: Radiator Cooled
Heat Rejection to Cooling System: 200 kW
Exhaust Gas Flow: 75 m³/min
Exhaust Gas Temperature: 550°C
Fuel Type: Diesel
Fuel Tank Capacity: 400 L
Approx. Fuel Consumption (Continuous): 50 L/hr
Approx. Fuel Consumption (Standby): 58 L/hr
Generator