Test monitoring units are use in the testing of sensors without interference with the production process. Please enquire for further product information and availability of similar products.
Description
467 Recent ViewsCall for more details
TNT 35 Test Monitoring Unit for Type 2 Sensors
Every 2 seconds, the test monitoring unit TNT 35 performs a periodic test on the protective function of the connected testable sensor, without interfering in the production process of the safeguarded machine. This rapid succession of periodic functional tests ensures a maximum of Type 2 functional safety.
Advantages • Test monitoring unit, Type 2, in accordance with EN/IEC 61496-1,-2 • Continuous cyclical testing (every 2 s) does not interrupt the operating function • 2 safety relay outputs with internal monitoring • Can be connected to all Leuze lumiflex Type 2 safety sensors • Selectable start and restart interlock • Integrated relay monitoring (EDM – external device monitoring) • Status outputs as pnp transistor outputs • LED indicators for all important functions and operating states • Requires minimal space in electronics cabinet due to compact design
TMC 66 Test Monitoring Unit with Muting for Type 2 Sensors
TMC 66 is a combination of a test monitoring unit and a muting controller. The connected testable Type 2 sensor and the testable muting sensors are checked every 2 seconds by means of a cyclical functional test without interfering in the machine function.
Advantages • Test monitoring unit, Type 2, with muting function in accordance with EN/IEC 61496-1.-2 • Safety relay output with failsafe monitoring • Continuous cyclical testing (every 2 s) does not interrupt the operating function • Can be connected to all common testable safety light barriers • Start/restart interlock and relay monitoring selectable • Processing of PLC control signals as muting initiator • Connection for two monitoring muting light indicators (required according to EN 61496-1) • Integrated muting restart mode (start with darkened BWS) • Separate status outputs as pnp transistor outputs
To contact Zone Safety Systems about Test Monitoring Units use Get a quote.
TNT 35 Test Monitoring Unit for Type 2 Sensors
Every 2 seconds, the test monitoring unit TNT 35 performs a periodic test on the protective function of the connected testable sensor, without interfering in the production process of the safeguarded machine. This rapid succession of periodic functional tests ensures a maximum of Type 2 functional safety.
Advantages • Test monitoring unit, Type 2, in accordance with EN/IEC 61496-1,-2 • Continuous cyclical testing (every 2 s) does not interrupt the operating function • 2 safety relay outputs with internal monitoring • Can be connected to all Leuze lumiflex Type 2 safety sensors • Selectable start and restart interlock • Integrated relay monitoring (EDM – external device monitoring) • Status outputs as pnp transistor outputs • LED indicators for all important functions and operating states • Requires minimal space in electronics cabinet due to compact design
TMC 66 Test Monitoring Unit with Muting for Type 2 Sensors
TMC 66 is a combination of a test monitoring unit and a muting controller. The connected testable Type 2 sensor and the testable muting sensors are checked every 2 seconds by means of a cyclical functional test without interfering in the machine function.
Advantages • Test monitoring unit, Type 2, with muting function in accordance with EN/IEC 61496-1.-2 • Safety relay output with failsafe monitoring • Continuous cyclical testing (every 2 s) does not interrupt the operating function • Can be connected to all common testable safety light barriers • Start/restart interlock and relay monitoring selectable • Processing of PLC control signals as muting initiator • Connection for two monitoring muting light indicators (required according to EN 61496-1) • Integrated muting restart mode (start with darkened BWS) • Separate status outputs as pnp transistor outputs