15 Amp 20m Construction Industrial Extension ...
“Construction Leads”:
For indoor, outdoor and harsh environments.
The “construction” lead has a larger diameter cable and longer maximum allowable length
from the outlet to the appliance than “heavy duty” leads.
It is suitable for use on sites that have few outlets.
Where the lead is connected to a temporary site power board a that is a long distance from the local distribution board and where voltage drop is a consideration.
The maximum length for general use: 65m
The maximum length for use with any equipment that has a high starting current: 35m
Applications
The extension lead is suitable for dry, damp and wet environments; areas of stress caused by vibration or impact they are resistant to abrasion, exposure to radiated heat and chemical contamination. Because of the black, flame retardant sheath, it is suitable for areas subject to fire hazard and hazardous locations like engineering workshops.
This extension lead recommended for applications where the cord is continually dragged behind a machine, e.g., floor polishers, floor grinders, etc.
Maximum Ambient temperature: 40°C
Maximum Continuous Length: 65m
Maximum current at 40°C: 15A
Cable Specifications:
Cable CSA:4mm²
Max Voltage: 06/1kV
Insulation: Ethylene-propylene rubber (EPR) R-EP-90 90 deg C Conductor
Sheath Colour: Black - UV, sunlight and weather resistant.
Cable Temperature Range: -25 deg C to +90 deg C (mobile) -40 deg c to +90 Deg C (fixed)
Maximum permissible short circuit temperature: 250 deg C for 1 Sec
To contact EEC Technical Services about 15 Amp 20m Construction Industrial Extension Lead Electrical Cable use Get a quote.
“Construction Leads”:
For indoor, outdoor and harsh environments.
The “construction” lead has a larger diameter cable and longer maximum allowable length
from the outlet to the appliance than “heavy duty” leads.
It is suitable for use on sites that have few outlets.
Where the lead is connected to a temporary site power board a that is a long distance from the local distribution board and where voltage drop is a consideration.
The maximum length for general use: 65m
The maximum length for use with any equipment that has a high starting current: 35m
Applications
The extension lead is suitable for dry, damp and wet environments; areas of stress caused by vibration or impact they are resistant to abrasion, exposure to radiated heat and chemical contamination. Because of the black, flame retardant sheath, it is suitable for areas subject to fire hazard and hazardous locations like engineering workshops.
This extension lead recommended for applications where the cord is continually dragged behind a machine, e.g., floor polishers, floor grinders, etc.
Maximum Ambient temperature: 40°C
Maximum Continuous Length: 65m
Maximum current at 40°C: 15A
Cable Specifications:
Cable CSA:4mm²
Max Voltage: 06/1kV
Insulation: Ethylene-propylene rubber (EPR) R-EP-90 90 deg C Conductor
Sheath Colour: Black - UV, sunlight and weather resistant.
Cable Temperature Range: -25 deg C to +90 deg C (mobile) -40 deg c to +90 Deg C (fixed)
Maximum permissible short circuit temperature: 250 deg C for 1 Sec