"Easy to use. Multiple quotes by most brands on the list. Effective platform indeed - Thank you"
How IndustrySearch works
1. Tell us what you need
in a few quick steps
2. Get personalised quotes
from expert suppliers
3. Compare and make the
best choice
Looking to buy the best Trox Ventilation Damper for sale? Get Quotes sends your requirements to expert suppliers in Australia so you get personalised quotes to compare Ventilation Damper prices, specifications, features and terms then choose the one that’s right for you. Also compare servicing, consumables and reviews, so you can buy with confidence.
TROX Australia | Indoor Air Conditioning and Ventilation. TROX is the leader in the development, manufacture and supply of components and systems for commercial air conditioning as well as commercial and Industrial ventilation installations.. Extensive and dedicated research has positioned TROX at the forefront in innovation in these fields.
Is a mechanical device installed in HVAC (Heating, Ventilation, and Air Conditioning) systems to control the flow of air and maintain the integrity of fire barriers in buildings. These dampers are designed to prevent the spread of fire and smoke through ventilation systems by closing off the ductwork in the event of a fire. They can also be used to regulate the flow of air in a building, improve indoor air quality, and reduce energy consumption. Fire & Ventilation Dampers are essential for maintaining the safety and comfort of occupants in commercial and industrial buildings.
Why do I need a Fire & Ventilation Damper?
Is a critical component of any building's fire protection system. It is designed to prevent the spread of smoke and fire through air ducts and ventilation systems. The damper works by automatically closing off the air supply to a particular area of the building in the event of a fire, preventing the spread of flames and smoke to other parts of the building. This helps to contain the fire and minimize damage, as well as providing a safe escape route for occupants. Additionally, fire and ventilation dampers are required by building codes and regulations to ensure compliance with safety standards. Overall, the installation of a fire and ventilation damper is essential to protect the building and its occupants in case of a fire.
What types of Fire & Ventilation Dampers are available?
Fire and ventilation dampers are essential components of a building's fire protection system. They are designed to prevent the spread of fire and smoke throughout a building by automatically closing off air ducts or openings in walls or ceilings in the event of a fire. There are several types of fire and ventilation dampers available, including:
Curtain Fire Dampers: These are used in vertical or horizontal ducts and are designed to shut off the duct in the event of a fire. They consist of a metal frame with a fire-resistant curtain that closes when exposed to high temperatures.
Ceiling Radiation Dampers: These are installed in ceilings and are designed to prevent fire and smoke from spreading through openings in the ceiling. They consist of a metal frame with a heat-sensitive damper blade that closes when exposed to high temperatures.
Smoke Dampers: These are designed to prevent the spread of smoke through air ducts. They are similar to curtain fire dampers but are specifically designed to control smoke rather than fire.
Combination Fire and Smoke Dampers: These are designed to prevent both fire and smoke from spreading through air ducts. They combine the features of curtain fire dampers and smoke dampers.
Ventilation Dampers: These are designed to regulate air flow in HVAC systems. They can be manually or automatically controlled and can be installed in both horizontal and vertical ducts.
Overall, the type of fire and ventilation damper required will depend on the specific needs of the building, its occupants, and its fire protection system.
What materials are used to make Fire & Ventilation Dampers?
Fire and ventilation dampers are typically made of a range of materials depending on the specific application and requirements. Some common materials used in the construction of these dampers include galvanized steel, aluminum, stainless steel, and various composite materials. Galvanized steel is often used in the construction of fire dampers due to its high-temperature resistance and durability. Aluminum is also commonly used in ventilation dampers due to its lightweight and corrosion-resistant properties. Stainless steel, on the other hand, is often used in the construction of dampers that are exposed to harsh environments or corrosive substances. Composite materials are also used in some applications as they offer a lightweight and cost-effective alternative to traditional materials. The choice of material for fire and ventilation dampers depends on various factors such as the temperature, pressure, and chemical composition of the air or gas being transported through the system.
How do I choose the right size Fire & Ventilation Damper for my application?
S play a critical role in ensuring safety and proper air flow in buildings. Choosing the right size damper is essential for optimal performance and compliance with building codes and regulations.
To select the appropriate size fire and ventilation damper, consider the following factors:
Duct size: The damper should be sized to fit the ductwork it will be installed in. Measure the width, height, and depth of the duct to determine the appropriate damper size.
Airflow requirements: The damper should be able to handle the required airflow for the specific application. Check the manufacturer's specifications for maximum airflow capacity.
Fire rating: Fire dampers must meet specific fire rating requirements based on the building occupancy and fire hazard level. Consult local building codes and regulations to determine the required fire rating for your application.
Type of damper: There are different types of fire and ventilation dampers, including curtain, blade, and louver dampers. Choose the type of damper that best suits your application and airflow requirements.
Installation location: The location of the damper can affect its performance and sizing requirements. For example, dampers located near corners or elbows in the ductwork may require larger sizes to ensure proper airflow.
Consult with a qualified HVAC professional or damper manufacturer to ensure proper sizing and installation of fire and ventilation dampers in your building.
How is a Fire & Ventilation Damper installed?
Installation involves several steps, including selecting the appropriate damper, preparing the opening for installation, positioning the damper, connecting the damper to the ductwork, and testing the damper for proper functionality.
The first step in installing a fire and ventilation damper is selecting the appropriate damper for the application. This involves considering factors such as the size of the damper, the type of ductwork it will be installed in, and the specific requirements of the building code.
Once the damper has been selected, the opening in the ductwork must be prepared for installation. This may involve cutting a hole in the ductwork, removing any debris or obstructions, and ensuring that the surrounding area is clean and free from any potential hazards.
The damper is then positioned in the opening and secured in place with screws or other fasteners. It is important to ensure that the damper is properly aligned with the ductwork and that there are no gaps or leaks around the edges of the installation.
Next, the damper is connected to the ductwork using appropriate connectors and seals. This may involve using specialized duct tape or other sealing materials to ensure a tight and secure connection.
Finally, the damper is tested for proper functionality, including checking for any leaks or gaps around the installation and verifying that the damper operates smoothly and effectively in response to fire or smoke conditions.
Overall, the installation of a fire and ventilation damper requires careful attention to detail and adherence to specific building codes and safety standards in order to ensure that the damper functions effectively and reliably in the event of a fire or other emergency.
What maintenance is required for a Fire & Ventilation Damper?
Maintenance for a Fire & Ventilation Damper includes regular inspections, cleaning, lubrication, and testing. Inspections should be done at least once a year to ensure the damper is in good condition and functioning properly. The damper should also be cleaned periodically to remove any debris or buildup that could impede its operation. Lubrication is necessary to keep the damper's moving parts working smoothly, and testing should be done regularly to ensure the damper can close and seal properly in case of a fire. Any necessary repairs or replacements should be made promptly to ensure the damper remains effective in preventing the spread of fire and smoke.
What certifications should I look for when buying a Fire & Ventilation Damper?
Certifications are important to ensure that the product meets safety and quality standards. The most common certifications to look for when buying a Fire & Ventilation Damper include UL (Underwriters Laboratories), FM (Factory Mutual), and CE (Conformité Européene). UL certification ensures that the damper meets safety standards set by the US National Fire Protection Association (NFPA). FM certification indicates that the damper has been tested and approved by Factory Mutual Global, a third-party testing and certification organization. CE certification indicates that the damper meets safety and quality standards set by the European Union. Other certifications to consider include ISO 9001 (quality management), ISO 14001 (environmental management), and OHSAS 18001 (occupational health and safety management).
What is the cost of a Fire & Ventilation Damper?
The cost of a fire and ventilation damper varies depending on the size, type, and manufacturer. Generally, the cost can range from a few hundred dollars to several thousand dollars per unit. It is recommended to consult with a professional HVAC contractor to determine the specific cost for your project.
Get 3+ Quotes Now - Compare prices, availability and quality. It’s free, quick and secure.
Back to top
Ventilation Damper Costs and Supplier Insights
The listed price of a Ventilation Damper for sale ranges from $50 to $500, averaging $275.
Use Get Quotes to receive personalised prices and proposals from trusted suppliers with top reviews and excellent service.
Buy a Ventilation Damper Near Me
Save time and delivery costs while getting fast support, by contacting Ventilation Damper suppliers near you.