Access to PROFIBUS PA devices through virtual mapping as a modular PROFINET device
Description
PROFINET, PROFIBUS, Plant Asset
149 Recent ViewsIn Stock
Re-use of Existing Power Conditioners in Technology Upgrade Projects
No PROFIBUS DP Intermediate Segment required
Prepared for Integration in Standard Engineering and Plant Asset Management Tools
Overview
Key Component for Transition to State-of-the-Art Technology
Simple replacement of installed PROFIBUS DP/PA segment couplers
Re-use of existing PROFIBUS PA segments without requiring modification
Support of PROFINET redundancy for increased reliability
Direct Connectivity to PROFIBUS Segments
Acting as PROFINET Device and PROFIBUS PA Master
Support of up to 4 PROFIBUS PA segments
Configuration, Parameterization and Plant Asset Management Using Standard Industry Tools
Supports major PROFINET engineering tools such as TIA Portal, Step7 and PC WORXS
Included CommDTM allowing use in FDT/DTM frame applications
EDD-based device parametrization using Siemens Simatic PDM
Technical Details
Hardware
Processor Status LEDs (Gateway)
Status LEDs (Fieldbus)
Altera Cyclone V SoC with dual-core ARM Cortex-A9 PWR (power supply), RUN (operation), ERR (error), CFG (configuration and update) SF (system fault), BF (bus fault)
Interfaces and Connectors
Ethernet
PROFIBUS PA
2 * IEEE 802.3 100BASE-TX / 10BASE-T, embedded PROFINET switch for daisy chain topology Connectors: RJ45 Protocol: PROFINET RT / IRT, Support of PROFINET redundancy protocols RESTful API interface for device configuration Up to 4 PROFIBUS PA (MBP) segments (refer to the section “Order Numbers”), Bus-powered Medium Attachment Unit (MAU): Fieldbus voltage range: 9 VDC ... 32 VDC, current consumption 10 mA, Connectors: 3-position screw connection, galvanically isolated
Physical Properties
Dimensions (H x W x D) Weight Power Supply
Operating / Storage Temperature Relative Humidity Cooling Coating Mounting Protection Class
100 mm x 35 mm x 105 mm About 0.25 kg 18 VDC ... 32 VDC; SELV/PELV power supply mandatory Typical input current: 200 mA, maximum input current: 1 A (allowing for in-rush current at switch-on) No power supply to PROFIBUS PA segments through pnGate PA -40 °C ... +70 °C / -40 °C ... +85 °C (see detailed mounting description in user manual) 10 % ... 95 %, non-condensing Convection, no fan Conformal coating based on ANSI / ISA-S71.04 G3 DIN rail 35 mm IP20
Downloads
Drivers & Software
Search and Configure V1.43.4 - for changing gateway IP settings
PDM libraries V3.4.1 - for integration into Siemens PDM
PACTware V4.1 - FDT frame application
PROFIdtm V2.00 - for usage in FDT frame applications
Manuals & Documentation
pnGate PA/pnGate PB V1.22 – Quick Startup Guide
pnGate PA/pnGate PB V1.22 – User Guide
Data Sheets
pnGate PA Data Sheet
Scope of Delivery
Hardware
pnGate PA Gateway
Software
FDT CommDTM, PACTware, Drivers and Tools
Documentation
On CD-ROM
Order Numbers
GCA-AL-024602
pnGate PA, PROFINET to PROFIBUS-PA Gateway. Supports up to 2 PROFIBUS PAsegments (up to 32 PA devices).
GCA-AL-024604
pnGate PA, PROFINET to PROFIBUS-PA Gateway. Supports up to 4 PROFIBUS PAsegments (up to 64 PA devices).
GCA-AL-024603
pnGate PA (for STAHL carrier), PROFINET to PROFIBUS-PA Gateway. Supports up to 4 PROFIBUS PA segments (up to 64 PA devices). For reversed mounting position on STAHL backplane.
To contact Ti2 Pty Ltd about Softing PROFINET to PROFIBUS PA Master Gateway use Get a quote.
Re-use of Existing Power Conditioners in Technology Upgrade Projects
No PROFIBUS DP Intermediate Segment required
Prepared for Integration in Standard Engineering and Plant Asset Management Tools
Overview
Key Component for Transition to State-of-the-Art Technology
Simple replacement of installed PROFIBUS DP/PA segment couplers
Re-use of existing PROFIBUS PA segments without requiring modification
Support of PROFINET redundancy for increased reliability
Direct Connectivity to PROFIBUS Segments
Acting as PROFINET Device and PROFIBUS PA Master
Support of up to 4 PROFIBUS PA segments
Configuration, Parameterization and Plant Asset Management Using Standard Industry Tools
Supports major PROFINET engineering tools such as TIA Portal, Step7 and PC WORXS
Included CommDTM allowing use in FDT/DTM frame applications
EDD-based device parametrization using Siemens Simatic PDM
Technical Details
Hardware
Processor Status LEDs (Gateway)
Status LEDs (Fieldbus)
Altera Cyclone V SoC with dual-core ARM Cortex-A9 PWR (power supply), RUN (operation), ERR (error), CFG (configuration and update) SF (system fault), BF (bus fault)
Interfaces and Connectors
Ethernet
PROFIBUS PA
2 * IEEE 802.3 100BASE-TX / 10BASE-T, embedded PROFINET switch for daisy chain topology Connectors: RJ45 Protocol: PROFINET RT / IRT, Support of PROFINET redundancy protocols RESTful API interface for device configuration Up to 4 PROFIBUS PA (MBP) segments (refer to the section “Order Numbers”), Bus-powered Medium Attachment Unit (MAU): Fieldbus voltage range: 9 VDC ... 32 VDC, current consumption 10 mA, Connectors: 3-position screw connection, galvanically isolated
Physical Properties
Dimensions (H x W x D) Weight Power Supply
Operating / Storage Temperature Relative Humidity Cooling Coating Mounting Protection Class
100 mm x 35 mm x 105 mm About 0.25 kg 18 VDC ... 32 VDC; SELV/PELV power supply mandatory Typical input current: 200 mA, maximum input current: 1 A (allowing for in-rush current at switch-on) No power supply to PROFIBUS PA segments through pnGate PA -40 °C ... +70 °C / -40 °C ... +85 °C (see detailed mounting description in user manual) 10 % ... 95 %, non-condensing Convection, no fan Conformal coating based on ANSI / ISA-S71.04 G3 DIN rail 35 mm IP20
Downloads
Drivers & Software
Search and Configure V1.43.4 - for changing gateway IP settings
PDM libraries V3.4.1 - for integration into Siemens PDM
PACTware V4.1 - FDT frame application
PROFIdtm V2.00 - for usage in FDT frame applications
Manuals & Documentation
pnGate PA/pnGate PB V1.22 – Quick Startup Guide
pnGate PA/pnGate PB V1.22 – User Guide
Data Sheets
pnGate PA Data Sheet
Scope of Delivery
Hardware
pnGate PA Gateway
Software
FDT CommDTM, PACTware, Drivers and Tools
Documentation
On CD-ROM
Order Numbers
GCA-AL-024602
pnGate PA, PROFINET to PROFIBUS-PA Gateway. Supports up to 2 PROFIBUS PAsegments (up to 32 PA devices).
GCA-AL-024604
pnGate PA, PROFINET to PROFIBUS-PA Gateway. Supports up to 4 PROFIBUS PAsegments (up to 64 PA devices).
GCA-AL-024603
pnGate PA (for STAHL carrier), PROFINET to PROFIBUS-PA Gateway. Supports up to 4 PROFIBUS PA segments (up to 64 PA devices). For reversed mounting position on STAHL backplane.
Trade With Confidence. The supplier of this item is approved as a Verified Supplier. Business registration, contact details and locations have been verified. Ti2 Pty Ltd are also proudly displaying these credentials: