This Portable Appliance Tester Complies to AS / NZS 3760. Protect life and property from faulty appliances with this tester.
Description
237 Recent ViewsIn Stock
Portable Appliance Tester - KEW 6205 Features
Battery operated
PASS / FAIL result
Color status back light
10 mA & 30 mA RCD test (Isolation transformer built in)
Memory function up to 999 data
Printer output
Complies to AS/NZS 3760
This instrument is suitable for performing tests as required by the following standards. AS/NZS 3760 In-service safety inspection and testing of electrical equipment.
Function
Tests of contents
Class I Test
• Protective conductor resistance (Test current 200mA DC nominal) • Insulation resistance test (250V or 500V) • Leakage current test (100-253V/50Hz) • Load current test (100-253V/50Hz)
Class II Test
• Insulation resistance test (250V or 500V) • Leakage current test (100-253V/50Hz) • Load current test (100-253V/50Hz)
Extension Lead Test
• Protective conductor resistance (Test current 200mA DC nominal) • Insulation resistance test (between Line/Neutral-Earth short, Line/Neutral) • Leakage current test (100-253V/50Hz) • Polarity test
RCD Test
• RCD test (10mA/30mA)
Mains voltage indlcation
Display range
30V-270V
Accuracy
±5V
Protective conductor resistance test
Measuring range
0.00-20.00Ω
Open circuit voltage
5V±0.4V DC
Measuring current
200mA DC(nominal value)
Accuracy
±3%rdg±5dgt
Insulation resistance test
Rated volatge
250V
500V
Measuring range
0.00-20.00MΩ
No-load voltage
250V DC +20%,-0%
500V DC +20%,-0%
Short circuit current
1.5mA DC or less
Accuracy
±2%rdg±3dgt
Load current/Leakage current test
Item
Load current
Leakage current
Mains voltage range
100-253V/50Hz
Measuring range
0.10-10.00A rms
0.10-20.00mA rms
Accuracy
±10%rdg±5dgt
±3%rdg±5dgt
RCD test
Rated voltage
230V -15% - +10%/50Hz
Rated current
10mA/30mA
Function
× 1
× 5
Test duration
0.0ms-500.0ms
0.0ms-40.0ms
Operating time accuracy
±2ms(?40ms),±8ms(>40ms)
General
Power source
LR6(AA)(1.5V) × 6
Applicable Standards
IEC/EN61010-1 CAT II 300V, IEC/EN61010-2-030, IEC/EN61010-031, EN61326-2-2, AS/NZ3760
7277(Mains lead), 7129A(Test lead with Alligator clip), 7161A(Flat test prod), 7276(Adaptor for Extension cord), 9193(Carrying case), 8928(Fuse[10A/250V]), 9121(Shoulder strap), Buckle, LR6(AA) x 6, Instruction manual
Optional Accessories
8263-USB(USB cable with "KEW Report(software)"), 7275(Printer cable:Mini Din 6pin-D-sub 9pin), 7248(Test lead with Alligator clip and Flat test probe)
To contact OBIAT Electronics Pty Ltd about Kyoritsu 6205 Portable Appliance Tester use Get a quote.
Portable Appliance Tester - KEW 6205 Features
Battery operated
PASS / FAIL result
Color status back light
10 mA & 30 mA RCD test (Isolation transformer built in)
Memory function up to 999 data
Printer output
Complies to AS/NZS 3760
This instrument is suitable for performing tests as required by the following standards. AS/NZS 3760 In-service safety inspection and testing of electrical equipment.
Function
Tests of contents
Class I Test
• Protective conductor resistance (Test current 200mA DC nominal) • Insulation resistance test (250V or 500V) • Leakage current test (100-253V/50Hz) • Load current test (100-253V/50Hz)
Class II Test
• Insulation resistance test (250V or 500V) • Leakage current test (100-253V/50Hz) • Load current test (100-253V/50Hz)
Extension Lead Test
• Protective conductor resistance (Test current 200mA DC nominal) • Insulation resistance test (between Line/Neutral-Earth short, Line/Neutral) • Leakage current test (100-253V/50Hz) • Polarity test
RCD Test
• RCD test (10mA/30mA)
Mains voltage indlcation
Display range
30V-270V
Accuracy
±5V
Protective conductor resistance test
Measuring range
0.00-20.00Ω
Open circuit voltage
5V±0.4V DC
Measuring current
200mA DC(nominal value)
Accuracy
±3%rdg±5dgt
Insulation resistance test
Rated volatge
250V
500V
Measuring range
0.00-20.00MΩ
No-load voltage
250V DC +20%,-0%
500V DC +20%,-0%
Short circuit current
1.5mA DC or less
Accuracy
±2%rdg±3dgt
Load current/Leakage current test
Item
Load current
Leakage current
Mains voltage range
100-253V/50Hz
Measuring range
0.10-10.00A rms
0.10-20.00mA rms
Accuracy
±10%rdg±5dgt
±3%rdg±5dgt
RCD test
Rated voltage
230V -15% - +10%/50Hz
Rated current
10mA/30mA
Function
× 1
× 5
Test duration
0.0ms-500.0ms
0.0ms-40.0ms
Operating time accuracy
±2ms(?40ms),±8ms(>40ms)
General
Power source
LR6(AA)(1.5V) × 6
Applicable Standards
IEC/EN61010-1 CAT II 300V, IEC/EN61010-2-030, IEC/EN61010-031, EN61326-2-2, AS/NZ3760
7277(Mains lead), 7129A(Test lead with Alligator clip), 7161A(Flat test prod), 7276(Adaptor for Extension cord), 9193(Carrying case), 8928(Fuse[10A/250V]), 9121(Shoulder strap), Buckle, LR6(AA) x 6, Instruction manual
Optional Accessories
8263-USB(USB cable with "KEW Report(software)"), 7275(Printer cable:Mini Din 6pin-D-sub 9pin), 7248(Test lead with Alligator clip and Flat test probe)
Trade With Confidence. The supplier of this item is approved as a Verified Supplier. Business registration, contact details and locations have been verified. OBIAT Electronics Pty Ltd are also proudly displaying these credentials: