The Oxy 4100/5100 sensor caps embody the smart connection of the sensor with the sample. To match individual requirements, the right sensor cap can be chosen from a variety of caps. Conveniently switch between the ranges by simply exchanging the sensor cap.
All required calibration parameters are stored in the sensor cap of the inline oxygen sensor. The Toolmaster® technology automatically detects the sensor cap and transfers all setup parameters to the sensor. Once the cap is mounted, inline measurement can start immediately.
Only Oxy 5100 supports the steps involved in setting up a predictive maintenance schedule for inline measurement.
The Oxy 5100 lifetime estimator estimates the remaining service life of the sensor cap in days and warns you when a new sensor cap is required. Warnings are automatically shown on the sensor display, and an updated lifetime estimation can be requested at any time.
The Oxy 4100/5100 inline oxygen sensors are suitable for hygiene applications in the beverage, pharmaceutical, and water treatment industries. Oxy 5100 fulfills international hygienic standards because it is EHEDG-certified Type EL – Class I and can be cleaned using all common CIP procedures. All materials that are in contact with the sample are FDA-compliant.
Oxy 4100/5100 is designed for cleaning and sterilization at temperatures up to 130 °C. The sensor is ready for in-spec operation only a few minutes after cleaning and sterilization, reducing downtimes to a minimum.
No special training is required to commission and operate the instrument. The sensor series are set up quickly and can be easily used with the touchscreen interface of the built-in evaluation unit, via the Pico 3000 software, or with the help of the mPDS 5 evaluation unit.
Oxy 5100 can be easily adapted to support several communications protocols including analog (4 mA to 20 mA), Modbus RTU, Modbus TCP, HART, PROFIBUS DP, PROFINET IO, and EtherNet/IP. The Oxy 4100 transmitter comes ready with analog outputs and a touchscreen interface.
The CO2 Purity Monitor features a compact system for monitoring the O2 content in pressurized CO2 lines. Driven by Oxy 5100, in combination with the integrated pressure sensor for automatic pressure compensation, the CO2 Purity Monitor is a compact, stand-alone solution.
For a non-pressurized measuring point, Oxy 5100 and the clever sensor caps are installed right after the conditioning system is set up.
Sensor caps | Ultra-trace range** | Trace range* | Wide range | Ultra-wide range** |
Measuring range (dissolved O2 in liquids) | - (Gas phase only) | 0 ppb to 2000 ppb | 0 ppm to 22.5 ppm | 0 ppm to 45 ppm |
Measuring range (gas phase O2 in CO2) | 0 ppmv to 200 ppmv (0 hPa to 0.2 hPa) |
0 % to 4.2 % O2 (0 hPa to 40 hPa) |
0 % to 50 % O2 (0 hPa to 500 hPa) |
0 % to 100 % O2 (0 hPa to 1000 hPa) |
Accuracy for liquids (the larger value is valid) | - (Gas phase only) | ≤ ± 1 ppb or ± 3 % | ≤ ± 0.042 ppm or ± 3 % | ≤ ± 0.1 ppm or ± 5 % |
Accuracy in gas phase (the larger value is valid) | ≤ ± 2 ppmv or ± 5 % | ≤ ± 25 ppmv or ± 3 % | ≤ ± 0.1 % O2 or ± 3 % | ≤ ± 0.2 % O2 or ± 5 % |
Sample temperature (non-freezing) | 0 °C to 40 °C | -5 °C to +65 °C (Oxy 4100: -5 °C to +40 °C) |
-5 °C to +65 °C (Oxy 4100: -5 °C to +40 °C) |
-5 °C to +40 °C |
CIP/SIP temperature | Not suitable for CIP/SIP | max. 99 °C, max. 130 °C (max. 30 min) | ||
Line pressure | max. 12 bar abs. (174 psi abs.), max. 5 bar abs. (72 psi abs.) for measurements in gas phase | |||
Certifications | - | EHEDG (Type EL - Class I)** | ||
Measuring Interval | 1 to 360 s (Oxy 4100: 15 s) | |||
Ambient temperature / Humidity | -5 °C to +50 °C / 0 % rH to 90 % rH (non-condensing) | |||
Power supply | SELV DC 24 V (DC 20 V to 30 V), max. 1.6 W | |||
Dimensions (HxWxD) | Oxy 4100/5100: 162x162x215 / Pressure sensor for CO2 Purity Monitor: 80x80x120 |
* Special sensor cap type available for harsh process conditions. Contact your Anton Paar representative.
** Not available for Oxy 4100.
To contact Anton Paar Australia about Anton Paar Inline Dissolved Oxygen Sensor: Oxy 4100/56100 use Get a quote.
The Oxy 4100/5100 sensor caps embody the smart connection of the sensor with the sample. To match individual requirements, the right sensor cap can be chosen from a variety of caps. Conveniently switch between the ranges by simply exchanging the sensor cap.
All required calibration parameters are stored in the sensor cap of the inline oxygen sensor. The Toolmaster® technology automatically detects the sensor cap and transfers all setup parameters to the sensor. Once the cap is mounted, inline measurement can start immediately.
Only Oxy 5100 supports the steps involved in setting up a predictive maintenance schedule for inline measurement.
The Oxy 5100 lifetime estimator estimates the remaining service life of the sensor cap in days and warns you when a new sensor cap is required. Warnings are automatically shown on the sensor display, and an updated lifetime estimation can be requested at any time.
The Oxy 4100/5100 inline oxygen sensors are suitable for hygiene applications in the beverage, pharmaceutical, and water treatment industries. Oxy 5100 fulfills international hygienic standards because it is EHEDG-certified Type EL – Class I and can be cleaned using all common CIP procedures. All materials that are in contact with the sample are FDA-compliant.
Oxy 4100/5100 is designed for cleaning and sterilization at temperatures up to 130 °C. The sensor is ready for in-spec operation only a few minutes after cleaning and sterilization, reducing downtimes to a minimum.
No special training is required to commission and operate the instrument. The sensor series are set up quickly and can be easily used with the touchscreen interface of the built-in evaluation unit, via the Pico 3000 software, or with the help of the mPDS 5 evaluation unit.
Oxy 5100 can be easily adapted to support several communications protocols including analog (4 mA to 20 mA), Modbus RTU, Modbus TCP, HART, PROFIBUS DP, PROFINET IO, and EtherNet/IP. The Oxy 4100 transmitter comes ready with analog outputs and a touchscreen interface.
The CO2 Purity Monitor features a compact system for monitoring the O2 content in pressurized CO2 lines. Driven by Oxy 5100, in combination with the integrated pressure sensor for automatic pressure compensation, the CO2 Purity Monitor is a compact, stand-alone solution.
For a non-pressurized measuring point, Oxy 5100 and the clever sensor caps are installed right after the conditioning system is set up.
Sensor caps | Ultra-trace range** | Trace range* | Wide range | Ultra-wide range** |
Measuring range (dissolved O2 in liquids) | - (Gas phase only) | 0 ppb to 2000 ppb | 0 ppm to 22.5 ppm | 0 ppm to 45 ppm |
Measuring range (gas phase O2 in CO2) | 0 ppmv to 200 ppmv (0 hPa to 0.2 hPa) |
0 % to 4.2 % O2 (0 hPa to 40 hPa) |
0 % to 50 % O2 (0 hPa to 500 hPa) |
0 % to 100 % O2 (0 hPa to 1000 hPa) |
Accuracy for liquids (the larger value is valid) | - (Gas phase only) | ≤ ± 1 ppb or ± 3 % | ≤ ± 0.042 ppm or ± 3 % | ≤ ± 0.1 ppm or ± 5 % |
Accuracy in gas phase (the larger value is valid) | ≤ ± 2 ppmv or ± 5 % | ≤ ± 25 ppmv or ± 3 % | ≤ ± 0.1 % O2 or ± 3 % | ≤ ± 0.2 % O2 or ± 5 % |
Sample temperature (non-freezing) | 0 °C to 40 °C | -5 °C to +65 °C (Oxy 4100: -5 °C to +40 °C) |
-5 °C to +65 °C (Oxy 4100: -5 °C to +40 °C) |
-5 °C to +40 °C |
CIP/SIP temperature | Not suitable for CIP/SIP | max. 99 °C, max. 130 °C (max. 30 min) | ||
Line pressure | max. 12 bar abs. (174 psi abs.), max. 5 bar abs. (72 psi abs.) for measurements in gas phase | |||
Certifications | - | EHEDG (Type EL - Class I)** | ||
Measuring Interval | 1 to 360 s (Oxy 4100: 15 s) | |||
Ambient temperature / Humidity | -5 °C to +50 °C / 0 % rH to 90 % rH (non-condensing) | |||
Power supply | SELV DC 24 V (DC 20 V to 30 V), max. 1.6 W | |||
Dimensions (HxWxD) | Oxy 4100/5100: 162x162x215 / Pressure sensor for CO2 Purity Monitor: 80x80x120 |
* Special sensor cap type available for harsh process conditions. Contact your Anton Paar representative.
** Not available for Oxy 4100.