Looking to buy the best Fastron Electronics Current Transformer for sale? Get Quotes sends your requirements to expert suppliers in Australia so you get personalised quotes to compare Current Transformer prices, specifications, features and terms then choose the one that’s right for you. Also compare servicing, consumables and reviews, so you can buy with confidence.
Fastron Electronics | Power Electronics, Process Control, Measurement Fastron Electronics is a privately owned company based in Melbourne, Australia specialising in supplying Components, Products and Solutions to the Energy Monitoring, Power Electronics, Process Control and Electrical Instrumentation markets.
- Fastron are importers, manufacturers and electrical/electronic design/development and systems engineers.
- Our aim is to select the ...
What is a current transformer and what is its purpose?
A current transformer (CT) is a type of transformer that is used to measure electric current. It is designed to produce an output current that is proportional to the input current, but at a reduced level. The purpose of a current transformer is to provide a safe and accurate means of measuring high currents in electrical systems. It is commonly used in power distribution systems, where it is used to measure the current flowing through power lines and to protect equipment from overcurrent conditions. CTs are also used in industrial applications, such as motor control and monitoring, and in electrical testing and measurement equipment.
What are the different types of current transformers available in Australia?
Split-core current transformers: These transformers have a split core that can be opened and closed around the conductor, making them easy to install without disconnecting the circuit.
Solid-core current transformers: These transformers have a solid core and are typically used in high-current applications.
Wound current transformers: These transformers have a primary winding and a secondary winding, and are used to step down high currents to a lower level for measurement or protection.
Rogowski coil current transformers: These transformers use a flexible coil to measure current, making them ideal for applications where space is limited.
Bar-type current transformers: These transformers have a bar-shaped core that is placed around the conductor, and are typically used in high-voltage applications.
The specific types of current transformers available in Australia may vary depending on the manufacturer and distributor.
How do I choose the right current transformer for my application?
Choosing the right current transformer for your application involves considering several factors such as the primary current rating, the secondary current rating, the accuracy class, the burden, the frequency, the insulation level, and the type of output signal required. It is important to select a current transformer that can handle the maximum current expected in the circuit, has an appropriate accuracy class for the measurement requirements, and can provide the desired output signal. Additionally, the transformer should be compatible with the electrical system and environment in which it will be used. Consulting with a qualified electrical engineer or supplier can help ensure the proper selection of a current transformer for your specific application.
What are the accuracy classes for current transformers and which one do I need?
Current transformers (CTs) are used to measure electrical current in power systems. They are classified based on their accuracy, which is determined by the degree of error in their measurements. The accuracy classes for CTs are:
Class 0.1: These CTs have an accuracy of ±0.1% at rated current and are used for high-precision measurements in laboratory and testing applications.
Class 0.2: These CTs have an accuracy of ±0.2% at rated current and are used for high-precision measurements in power systems.
Class 0.5: These CTs have an accuracy of ±0.5% at rated current and are used for accurate measurements in power systems.
Class 1: These CTs have an accuracy of ±1% at rated current and are used for general-purpose measurements in power systems.
Class 3: These CTs have an accuracy of ±3% at rated current and are used for protection and control applications in power systems.
The accuracy class of a CT depends on the application and the required level of accuracy. For example, if you need to measure current in a laboratory or testing environment, you may need a Class 0.1 CT. However, if you need to measure current in a power system for general-purpose applications, a Class 1 CT may be sufficient. It is important to choose the appropriate accuracy class to ensure accurate measurements and safe operation of the power system.
What is the maximum current rating for current transformers and how do I determine the required rating for my application?
The maximum current rating for current transformers varies depending on the manufacturer and model. However, they typically range from a few milliamperes to several thousand amperes. To determine the required rating for your application, you need to consider the maximum current that will flow through the primary conductor and select a current transformer with a rating that is equal to or greater than that value. It is also important to consider the accuracy class, burden, and frequency range of the current transformer to ensure it meets the requirements of your application.
What are the installation requirements for current transformers?
Current transformers (CTs) are used to measure the current flowing through a conductor. They are commonly used in power systems to measure the current flowing through high-voltage lines. The installation requirements for CTs include:
Proper selection of CTs: CTs should be selected based on the rated primary current, rated secondary current, and accuracy class. The CTs should be selected to match the current rating of the system they are being installed in.
Mounting: CTs should be mounted in a location that is easily accessible for maintenance and inspection. They should be mounted securely to prevent movement or vibration.
Wiring: The wiring between the CTs and the measuring instrument should be kept as short as possible to minimize the effect of resistance and inductance. The wiring should be properly insulated and protected from mechanical damage.
Grounding: CTs should be grounded to prevent electrical shock and to ensure accurate measurement. The grounding should be done according to local electrical codes.
Testing: CTs should be tested before installation to ensure they are functioning properly. They should also be tested periodically to ensure they continue to function accurately.
Maintenance: CTs should be inspected and maintained regularly to ensure they are functioning properly. Any damaged or malfunctioning CTs should be replaced immediately.
How do I test the accuracy of a current transformer?
To test the accuracy of a current transformer, follow these steps:
Connect the current transformer to a known load, such as a resistor or a current source.
Measure the output voltage of the current transformer using a voltmeter or an oscilloscope.
Calculate the current ratio of the current transformer by dividing the output voltage by the input current.
Compare the calculated current ratio with the rated current ratio of the current transformer. If the two values are within a certain tolerance, the current transformer is accurate.
Repeat the test at different load levels to ensure that the current transformer is accurate across a range of currents.
If the current transformer is found to be inaccurate, it may need to be calibrated or replaced.
What are the maintenance requirements for current transformers?
Current transformers (CTs) are used to measure the current flowing in a circuit. They are essential components of power systems and need to be maintained regularly to ensure their accuracy and reliability. The maintenance requirements for CTs include:
Regular inspection: CTs should be inspected regularly to check for any signs of damage, such as cracks or corrosion.
Cleaning: CTs should be cleaned regularly to remove any dirt or debris that may have accumulated on the surface. This can be done using a soft cloth or brush.
Calibration: CTs should be calibrated periodically to ensure their accuracy. This can be done using a calibration device or by comparing the readings of the CT with those of a reference standard.
Testing: CTs should be tested periodically to check their performance under different load conditions. This can be done using a test set or by applying a known current to the CT and measuring the output.
Replacement: CTs that are damaged or no longer functioning properly should be replaced immediately to avoid any safety hazards or damage to the equipment.
Overall, regular maintenance of CTs is essential to ensure their accuracy and reliability, and to prevent any potential safety hazards.
What is the lead time for ordering a current transformer in Australia?
It is recommended to contact a local supplier or manufacturer for more information on lead times.
What is the warranty period for current transformers and what does it cover?
However, the warranty period and coverage can vary depending on the manufacturer and the product. It is recommended to check the manufacturer's website or contact their customer service for more information on the warranty period and coverage of their current transformers.
Get 3+ Quotes Now - Compare prices, availability and quality. It’s free, quick and secure.
Back to top
Current Transformer Costs and Supplier Insights
Use Get Quotes to receive personalised prices and proposals from trusted suppliers with top reviews and excellent service.
Buy a Current Transformer Near Me
Save time and delivery costs while getting fast support, by contacting Current Transformer suppliers near you.