The DIGISTANT® 4411 universal precision handheld calibrator can be used as a general purpose current and voltage source which is ideal for testing and calibrating all measuring instruments and control devices within its range of capacity.
Description
39 Recent ViewsIn Stock
Model 4411 from Burster is used to simulate a transducer, measures voltage up to 30VDC and currents up to 24mA and is capable as a small manageable checking and calibration device for process technology in field. The portable calibration device has many other applications in the metrology including:
calibration of pointer, indication instrument and recorders
simulation of thermocouples
plotting of components characteristics and checking of amplifiers, transducers, etc.
The function SINK can simulate a 2 wire transducer in a current loop. The output level can be changed between 4, 8, 12, 16 and 20 mA signals by one touch for the “4-20 mA” output, and between 1, 2, 3, 4 and 5 V DC signals for the “1-5 V” output, for efficient calibration work. While the “ramp function” increases and decreases the output level to the present level at a constant rate for the selected sweep time (16 or 32 seconds).DIGISTANT® model 4462 can be used either as a standalone table-top device, or in automatic, computer assisted manufacturing and testing systems. Its applications include:
calibration of current and DC voltage meters
testing of thermocouples
calibration of controllers, sensors, detectors, and other devices used in process control
integrated ramp function for open-loop process control
Products
Measuring ranges
Accuracy
Temperature
Traits
High precision Calibration Source DIGISTANT®Model 4462
±30V(±60V); ±52mA(±22mA); Thermocouple: 14 types
0.003% Rdg. (error limit)
5?..23?..40?
– Simulation for all conventional thermocouple types; – Standard with RS232 & IEEE488 interface, USB and Ethernet; – Current “SINK”.
To contact Bestech Australia about Bestech Current and Voltage Calibrators | DIGISTANT 4411 use Get a quote.
Model 4411 from Burster is used to simulate a transducer, measures voltage up to 30VDC and currents up to 24mA and is capable as a small manageable checking and calibration device for process technology in field. The portable calibration device has many other applications in the metrology including:
calibration of pointer, indication instrument and recorders
simulation of thermocouples
plotting of components characteristics and checking of amplifiers, transducers, etc.
The function SINK can simulate a 2 wire transducer in a current loop. The output level can be changed between 4, 8, 12, 16 and 20 mA signals by one touch for the “4-20 mA” output, and between 1, 2, 3, 4 and 5 V DC signals for the “1-5 V” output, for efficient calibration work. While the “ramp function” increases and decreases the output level to the present level at a constant rate for the selected sweep time (16 or 32 seconds).DIGISTANT® model 4462 can be used either as a standalone table-top device, or in automatic, computer assisted manufacturing and testing systems. Its applications include:
calibration of current and DC voltage meters
testing of thermocouples
calibration of controllers, sensors, detectors, and other devices used in process control
integrated ramp function for open-loop process control
Products
Measuring ranges
Accuracy
Temperature
Traits
High precision Calibration Source DIGISTANT®Model 4462
±30V(±60V); ±52mA(±22mA); Thermocouple: 14 types
0.003% Rdg. (error limit)
5?..23?..40?
– Simulation for all conventional thermocouple types; – Standard with RS232 & IEEE488 interface, USB and Ethernet; – Current “SINK”.
Customers: Auto/Transport, Defence,Water/Wastewater, Research