MKT 10 is a lightweight portable handheld thermometer. It comes with one sensor and a carrying case for safe transport. With its measuring accuracy of 0.01 °C it is ideal for precise at-line measurements and quick measurements on site
Description
Documents
Measuring uncertainty 0.01 °C
Key features
Measuring uncertainty over the whole measuring range: 0.01 °C
For at-line measurements with a handheld instrument
Lightweight and portable
Highest accuracy
EN 60751 for industrial Platinum Resistance Thermometers (PRT)
Resolution: 0.001 °C (1 mK) with MKT 10
Measuring uncertainty over the whole measuring range 0.01 °C with MKT 10
ITS-90 for standard thermometers (SPRT: Standard Platinum Resistance Thermometer) with MKT 50
With MKT 50 comparison calibration (PRT) or fixed point calibration (SPRT) is possible.
Flexible power supply and communication
Battery-operated
The high precision thermometers can be used in the lab or field as portable thermometers working from the battery.
MKT 10: Power over Ethernet (PoE) – ecologically friendly power supply for less use of batteries
Long-time experience
Anton Paar has decades of experience in density measurement which goes hand in hand with highly accurate temperature measurement since accurate temperature measurement is the basis for accurate density measurement.
Versatile applications
Ideal for different applications: from temperature measurement in the production process to different calibrations in the lab
MKT 10 provides maximum flexibility and at-line measurements with a handheld instrument.
Technical specifications
MKT 10
Measuring range
Temperature
0 °C to 100 °C (32 °F to 212 °F)
Resistance
100 Ω to 140 Ω
Resolution
Temperature
1 mK
Resistance
0.4 mΩ
Measurement uncertainty*
Temperature
< 10 mK
Resistance
< 4 mΩ
Measuring sensor
Pt 100 (EN 60751)
Measuring current
1 mADC
Internal reference resistor
400 Ω (Vishay Precision Group, VHP 101)
Number of sensor inputs
1
Sensor connection
4-wire, soldered
Measuring time
1 second (for one channel)
Data outputs
LAN (PoE, 10 Mbit)
Ambient operating temperature
0 °C to 35 °C (for highest accuracy 20 °C to 25 °C recommended)
Power supply
4× AA batteries or Power over Ethernet (PoE)
Dimensions (L × W × H)
200 mm × 100 mm × 35 mm (7.8 in × 3.4 in × 1.4 in)
Weight
approx. 500 g (1.1 lbs)
*) refers to the calibration of the reference resistor without contribution of the sensor (confidence level: 95 %, number of measurement values: 50, reference temperature: 23 °C)
To contact Anton Paar Australia about Anton Paar Precision Portable Thermometer | MKT 10 use Get a quote.
Key features
Measuring uncertainty over the whole measuring range: 0.01 °C
For at-line measurements with a handheld instrument
Lightweight and portable
Highest accuracy
EN 60751 for industrial Platinum Resistance Thermometers (PRT)
Resolution: 0.001 °C (1 mK) with MKT 10
Measuring uncertainty over the whole measuring range 0.01 °C with MKT 10
ITS-90 for standard thermometers (SPRT: Standard Platinum Resistance Thermometer) with MKT 50
With MKT 50 comparison calibration (PRT) or fixed point calibration (SPRT) is possible.
Flexible power supply and communication
Battery-operated
The high precision thermometers can be used in the lab or field as portable thermometers working from the battery.
MKT 10: Power over Ethernet (PoE) – ecologically friendly power supply for less use of batteries
Long-time experience
Anton Paar has decades of experience in density measurement which goes hand in hand with highly accurate temperature measurement since accurate temperature measurement is the basis for accurate density measurement.
Versatile applications
Ideal for different applications: from temperature measurement in the production process to different calibrations in the lab
MKT 10 provides maximum flexibility and at-line measurements with a handheld instrument.
Technical specifications
MKT 10
Measuring range
Temperature
0 °C to 100 °C (32 °F to 212 °F)
Resistance
100 Ω to 140 Ω
Resolution
Temperature
1 mK
Resistance
0.4 mΩ
Measurement uncertainty*
Temperature
< 10 mK
Resistance
< 4 mΩ
Measuring sensor
Pt 100 (EN 60751)
Measuring current
1 mADC
Internal reference resistor
400 Ω (Vishay Precision Group, VHP 101)
Number of sensor inputs
1
Sensor connection
4-wire, soldered
Measuring time
1 second (for one channel)
Data outputs
LAN (PoE, 10 Mbit)
Ambient operating temperature
0 °C to 35 °C (for highest accuracy 20 °C to 25 °C recommended)
Power supply
4× AA batteries or Power over Ethernet (PoE)
Dimensions (L × W × H)
200 mm × 100 mm × 35 mm (7.8 in × 3.4 in × 1.4 in)
Weight
approx. 500 g (1.1 lbs)
*) refers to the calibration of the reference resistor without contribution of the sensor (confidence level: 95 %, number of measurement values: 50, reference temperature: 23 °C)